蓄(xu)電池的(de)放(fang)電試(shi)驗(yan)有何(he)規(gui)定?
蓄(xu)電池核對(dui)性(xing)放電(dian)周期對(dui)於(yu)“電力系(xi)統(tong)”有具(ju)體(ti)的規(gui)定:
蓄(xu)電池核對(dui)性(xing)放電(dian)試(shi)驗(yan)檢(jian)查(zha)應(ying)嚴bai格按照《電(dian)力(li)系(xi)統(tong)用蓄(xu)電池直流(liu)電(dian)源裝(zhuang)置運(yun)行與維護技術(shu)規(gui)程(cheng)》(DL/T724-2000)的要(yao)求進(jin)行,並註意以(yi)下要(yao)求:
(1)壹(yi)組閥(fa)控(kong)蓄(xu)電池變(bian)電所中(zhong)只(zhi)有壹(yi)組電池(chi),不能(neng)退(tui)出運(yun)行,也(ye)不能(neng)做(zuo)全(quan)核對(dui)性(xing)放電(dian)時(shi),允許用(yong)I10電流(liu)放(fang)出其額(e)定容(rong)量(liang)的(de)50或(huo)30,進(jin)行半核對(dui)性(xing)放電(dian)試(shi)驗(yan);若(ruo)zhi有備(bei)用閥(fa)控(kong)蓄(xu)電池組作臨時(shi)代用,該組閥(fa)控(kong)蓄(xu)電池可(ke)作全核對(dui)性(xing)放電(dian)。
(2)兩(liang)組蓄(xu)電池變(bian)電所中(zhong)若(ruo)具有兩(liang)組閥(fa)控(kong)蓄(xu)電池,可(ke)先(xian)對(dui)其中(zhong)壹(yi)組閥(fa)控(kong)蓄(xu)電池組進(jin)行全核對(dui)性(xing)放電(dian),若經(jing)過3次全(quan)核對(dui)性(xing)放充電(dian),蓄(xu)電池組容dao量(liang)均(jun)達(da)不到額(e)定容(rong)量(liang)的(de)80以上,可(ke)認(ren)定為此組閥(fa)控(kong)蓄(xu)電池不符(fu)合使(shi)用要(yao)求,應(ying)安(an)排更換(huan)。
(3)閥(fa)控(kong)蓄(xu)電池核對(dui)性(xing)放電(dian)周期新(xin)安(an)裝或(huo)大修(xiu)後的閥(fa)控(kong)蓄(xu)電池組,必(bi)須進(jin)行全核對(dui)性(xing)放電(dian)試(shi)驗(yan)專(zhuan);以(yi)後運(yun)行第1年(nian)、每(mei)隔(ge)2~3年(nian)進(jin)行壹(yi)次(ci)核對(dui)性(xing)試(shi)驗(yan),運(yun)行了6年(nian)以後的閥(fa)控(kong)蓄(xu)電池,應(ying)每(mei)年(nian)作壹(yi)次(ci)核對(dui)性(xing)放電(dian)試(shi)驗(yan)
建議:
對(dui)於(yu)長(chang)期浮充、不常停電的(de)蓄(xu)電池組每(mei)月(yue)進(jin)行壹(yi)次(ci)淺放(fang)電(dian),每(mei)季度或(huo)半(ban)年(nian)進(jin)行壹(yi)次(ci)核對(dui)性(xing)放電(dian)。如(ru)此操(cao)作對(dui)於(yu)蓄(xu)屬電池(chi)的(de)壽(shou)命可(ke)起(qi)到維護保養(yang)得(de)作用。