產品(pin)名(ming)稱(cheng):接(jie)地(di)電(dian)阻電(dian)子搖(yao)表
更(geng)新時間(jian):2025-10-24
產品(pin)特(te)點:接(jie)地(di)電(dian)阻電(dian)子搖(yao)表廣(guang)泛應(ying)用(yong)於(yu)電(dian)力、電(dian)信(xin)、氣(qi)象、油田、建築(zhu)及(ji)工業(ye)電(dian)氣(qi)設(she)備(bei)等的(de)接(jie)地(di)電(dian)阻測(ce)量(liang)、回路(lu)電(dian)阻測(ce)量(liang)。
接地(di)電(dian)阻電(dian)子搖(yao)表的(de)詳細(xi)資(zi)料(liao):
接(jie)地(di)電(dian)阻電(dian)子搖(yao)表測(ce)量(liang)接線如下(xia)圖(tu)
圖(tu)2三極(ji)法(fa)測(ce)量(liang)接線示(shi)意(yi)圖(tu)
說明:電(dian)壓極(ji)2(P2),接(jie)地(di)網(wang)(C2)兩(liang)線必(bi)需(xu)都要連(lian)接在儀器(qi)上(shang),然後(hou)按(an)測(ce)量(liang)操(cao)作步驟進(jin)行測(ce)試(shi)。
2、測(ce)試(shi)操(cao)作步驟
1)首(shou)先檢(jian)查(zha)用(yong)於(yu)試(shi)驗(yan)的(de)電(dian)流(liu)線、電(dian)壓線和(he)地(di)網(wang)線是(shi)否(fou)有(you)斷路(lu)現(xian)象(xiang)(可(ke)以用(yong)萬(wan)用(yong)表(biao)測(ce)量(liang)),地(di)樁上(shang)的(de)鐵(tie)銹(xiu)是否清除(chu)幹(gan)凈,其埋(mai)進(jin)深度是(shi)否合適(>0.5米(mi)),同(tong)時檢(jian)查(zha)測(ce)試(shi)線與(yu)地(di)樁的(de)連(lian)接是否(fou)導(dao)通(tong),如未導通(tong),請(qing)處(chu)理後(hou)重(zhong)新連(lian)接。
2)電(dian)流(liu)測(ce)試(shi)線與(yu)電(dian)壓測(ce)試(shi)線的(de)長(chang)度比為1:0.618,電(dian)流(liu)測(ce)試(shi)線的(de)長(chang)度應(ying)是地(di)網(wang)對角(jiao)線的(de)3—5倍。
3)電(dian)流(liu)測(ce)試(shi)線和(he)電(dian)壓測(ce)試(shi)線按(an)規(gui)定(ding)的(de)長(chang)度將(jiang)壹端與(yu)儀器(qi)相接後(hou)平(ping)行放出(chu)。另(ling)壹端分(fen)別接在兩(liang)支(zhi)地(di)樁上(shang)(如圖(tu)2所示(shi))。
4)將(jiang)已放好(hao)的(de)測(ce)試(shi)線檢(jian)查(zha)壹遍,將萬(wan)用(yong)表(biao)壹端接(jie)電(dian)流(liu)線或(huo)電(dian)壓線,另(ling)壹端接(jie)地(di)網(wang)線如無阻值顯(xian)示(shi)即(ji)為斷路(lu),確(que)認(ren)完(wan)好再進行測(ce)試(shi)。
接地(di)電(dian)阻電(dian)子搖(yao)表主(zhu)要(yao)作用(yong):
1.精確(que)測(ce)量(liang)大型接(jie)地(di)網(wang)接(jie)地(di)阻抗、接(jie)地(di)電(dian)阻、接地(di)電(dian)抗;
2.精確(que)測(ce)量(liang)大型接(jie)地(di)網(wang)場區地(di)表(biao)電(dian)位梯度;
3.精確(que)測(ce)量(liang)大型接(jie)地(di)網(wang)接(jie)觸電(dian)位差、接(jie)觸電(dian)壓、跨(kua)步電(dian)位差、跨(kua)步電(dian)壓;
4.精確(que)測(ce)量(liang)大型接(jie)地(di)網(wang)轉(zhuan)移電(dian)位;
5.測(ce)量(liang)接地(di)引(yin)下(xia)線導(dao)通(tong)電(dian)阻;
6.測(ce)量(liang)土(tu)壤(rang)電(dian)阻率
技(ji)術(shu)參數
1、阻抗測(ce)量(liang)範(fan)圍(wei):0Ω~200Ω
2、分辨率:0.001Ω
3、測(ce)量(liang)誤差:±(讀數×2%+0.005Ω)
4、抗工(gong)頻50Hz 電(dian)壓幹(gan)擾(rao)能(neng)力:10V
5、測(ce)試(shi)電(dian)流(liu)波形(xing):正(zheng)弦(xian)波(bo)
6、測(ce)試(shi)電(dian)流(liu)頻率(lv):45Hz/55Hz 雙(shuang)頻(pin)
7、大輸出(chu)電(dian)流(liu):5A
8、大輸出(chu)電(dian)壓:400V
9、測(ce)量(liang)線要(yao)求(qiu): 電(dian)流(liu)線銅(tong)芯(xin)截面(mian)積(ji)≥2.0mm2
電(dian)壓線銅(tong)芯(xin)截面(mian)積(ji)≥1.5mm2
10、供電(dian)電(dian)源:AC220V±10%,50Hz
11、外(wai)形(xing)尺寸:440×350×210
12、儀器(qi)重(zhong)量:10kg
| 如果(guo)妳(ni)對接(jie)地(di)電(dian)阻電(dian)子搖(yao)表感(gan)興(xing)趣(qu),想了(le)解更(geng)詳細(xi)的(de)產品(pin)信(xin)息,填(tian)寫(xie)下(xia)表(biao)直接(jie)與(yu)廠(chang)家聯(lian)系: |